MEASUREMENT RANGES
DC Voltage: 200mV / 2V / 20V / 200V / 1000V ± (0.5% + 1).
AC Voltage: 200mV / 2V / 20V / 200V / 750V ± (0.8% + 3).
DC current: 20 µA / 2 mA / 200 mA / 10 A ± (0.8% + 1).
AC current: 20 µA / 2 mA / 200 mA / 10 A ± (1% + 3).
Rezystancja: 200 Ohm / 2 kOhm / 20 kOhm / 200 kOhm / 2 MOhm / 20 MOhm / 2000 MOhm ±(0,8%+1).
Capacitance: 20 nF / 200 nF / 2 µF / 100 µF ± (2.5% + 5).
Inductance: 2mH / 20mH / 200mH / 20H ± (2% + 10).
Frequency: 1 Hz-10 MHz ± (0.1% + 3).
Temperature: -40°C - 1000°C ±(1%+3); -40°F – 1832°F ±(1%+4).
Test diod
Continuity check
Checking TTL logic states
ADDITIONAL FUNCTIONS
Manual change of measuring ranges.
Temperature measurement on the Celsius and Fahrenheit scale.
Automatic shutdown.
Freezing the last reading.
Memory of the highest reading.
Low battery indicator.
Backlit LCD screen.
GENERAL FEATURES
DC input impedance: approx. 10 MOhm.
Power supply: 9V battery (6F22).
Display size: 53 x 62 mm.
Accessories: Battery, test leads, short test leads with alligator clips, temperature probe, test socket, holster.